ADMIN@THERMONICINDIA.COM +91 63519 09676

Fire Hydrant Pump Panel – Electric & Diesel Drive

Power Lines
Customer Support Get in Touch

A Thermonic Fire Hydrant Pump Panel is an essential part of firefighting systems, designed to automatically operate jockey pumps, main electric pumps, and diesel engine-driven pumps in compliance with NFPA/UL/FM/TAC/IS standards.

  • Jockey Pump: Maintains pressure for minor leaks and avoids frequent main pump operation
  • Main Electric Pump: Provides the required firefighting water flow during emergencies
  • Diesel Engine Pump: Ensures complete backup in case of electrical power failure

The Thermonic Fire Panel continuously senses line pressure via pressure switches and automatically sequences pump operation. Manual and Auto controls are also provided for reliability during emergency conditions.

Key Benefits of Thermonic Fire Panels:

  • Uninterrupted Fire Safety – Automatic sequencing of jockey, main, and diesel pumps
  • Failsafe Design – Diesel engine ensures 100% backup during power outages
  • Compliance – Built as per NFPA/UL/FM/TAC/IS standards
  • Safety First – Engine and pump protections with alarms and interlocks
  • Customizable – Available for single, dual, or multi-pump fire systems

Thermonic Electric & Diesel Fire Hydrant Panels are designed and tested to meet global and Indian standards:

  • 🌐 NFPA 20 – Standard for Installation of Fire Pumps
  • 🇮🇳 IS 12469 / IS 13947 – Indian Standards for Fire Pump Controllers & Switchgear
  • ⚙️ IEC 61439 / IS 8623 – Low-Voltage Switchgear Assemblies
  • 🔰 UL / FM / TAC Compliance – Fire Safety Approvals (on request)
  • 💡 ISO 9001: 2015 – Certified Quality Management System

✅ Each panel undergoes rigorous routine testing for electrical integrity, control logic accuracy, and fail-safe changeover between electric & diesel modes.

Thermonic Fire Hydrant Pump Panels (Electric & Diesel Drive) are suitable for all major firefighting applications where redundancy and continuity are critical:

  • 🏢 High-rise & Commercial Buildings – Automatic control of both power and backup fire pumps.
  • 🏭 Industrial Plants & Refineries – Uninterrupted firefighting operation under power failure.
  • 🛢 Oil & Gas, Chemical & Hazardous Sites – Reliable dual-drive fire water systems.
  • ✈️ Airports & Infrastructure Projects – NFPA-compliant emergency operation panels.
  • 🏨 Hospitals & Warehouses – Dual redundancy for 24 × 7 fire safety.

🔥 Engineered for critical facilities where continuous water flow must never stop — even during a total power outage.

All Thermonic Dual Drive Panels undergo comprehensive pre-dispatch testing and inspection.

✅ Routine Tests:

  • 🔍 Visual & Dimensional Inspection
  • ⚙️ Auto/Manual Functional Test (Electric and Diesel)
  • 🔄 Pressure Switch Simulation and Auto Sequencing Test
  • 🚨 Fail-safe Changeover Verification
  • ⚡ Insulation Resistance & High Voltage Dielectric Test

🧪 Special Tests (on Request):

  • 🌡 Endurance Test for Auto/Manual Cycles
  • 🔗 Diesel Start Interlock Reliability Test

📑 Documentation & Certificates:

  • 📄 Routine & Type Test Reports
  • 🎯 Calibration Certificates
  • 🏗 NFPA / IS / TAC Compliance Certificates

Each Thermonic panel is built with complete transparency and client approval before manufacturing — ensuring accuracy and compliance.

🧾 Documents Shared with Client (Before Production):

  • 📐 GA Drawing – Combined layout for Electric & Diesel sections
  • 🔌 SLD – Control sequence and Auto Changeover Logic
  • ⚙️ BOM – Switchgear, Contactors, Relays & Diesel Controller Modules
  • 📘 Technical Notes – NFPA Guidelines & Interlock Schemes
  • 🧠 Control Scheme – Auto/Manual operation with diesel backup activation

💡 Thermonic Advantages:

  • ⚡ Fully automatic changeover between electric and diesel drive
  • 🚨 Inbuilt alarms for low oil, high temperature, low fuel, battery fail, and phase failure
  • 🔗 Integration with Fire Alarm, Pressure Switch, and SCADA systems
  • 🔥 Compact and service-friendly dual-compartment design

Thermonic Electric & Diesel Fire Hydrant Panels can be customized based on project-specific requirements and site conditions:

  • ⚙️ Pump Capacity – Electric pump up to 250 HP | Diesel pump up to 300 HP.
  • 🧭 Operation Modes – Auto / Manual / Emergency.
  • 🔌 Starter Type – Star-Delta (Electric) + 12 V/24 V Diesel Start Control.
  • 🚨 Protections – Overload, Dry Run, Low Oil Pressure, High Temperature, Battery Fail.
  • 🏗️ Enclosures – CRCA powder-coated IP54/IP65 | SS optional for outdoor use.
  • 🔗 Integration – Pressure Switch, Flow Switch, Fire Alarm Panel, SCADA/BMS Interface.
🔥 Thermonic Electric & Diesel Drive Panels combine redundancy, reliability, and safety to ensure non-stop firefighting operation in critical applications.

Thermonic Star-Delta Fire Hydrant Panels are suitable for all installations where reliable and smooth motor starting is essential during fire emergencies:

  • 🏢 High-Rise & Commercial Buildings – Automatic hydrant control for sprinkler systems.
  • 🏭 Industrial Plants & Factories – Continuous water-supply control for firefighting networks.
  • 🛢 Oil, Gas & Petrochemical Units – Heavy-duty protection for hazardous environments.
  • ✈️ Airports, Power Stations & Metro Projects – Reliable motor starting with reduced current draw.
  • 🏨 Hospitals, Hotels & Institutions – 24×7 firefighting system readiness.

🔥 Thermonic Star-Delta Panels are ideal for larger motors where smooth, reliable, and energy-efficient starting is essential.